Skip to main content

Inspection visit

Pre-licensing visit

SONNET HILLLicense 435202780
Clean visit · 0 citations

Inspector’s narrative

What the inspector wrote

Licensing Program Analysts (LPAs) Yatfai Eric Ng, Anna Bui, and Ryker Heberle conducted an announced pre-licensing inspection. LPAs met with the representative - Executive Director (ED) David Hahklotubbe. This facility was 3-story building, had a capacity of 80 residents. Fire clearance approved for 80 non-ambulatory. First floor had a dining room for residents. Second floor was for memory care unit and third floor was for assisted living residents. This facility was not licensed before and had no resident currently. LPAs toured the facility inside and outside with ED. A device was installed at the entrance to check temperature of the visitors. A sign-in sheet and COVID-19 questionnaire were present at the reception area. The facility was well lit and in good repair, LPA did not see any damaged window screens, cracked floor, or broken furniture, etc. Facility's living room and dining room were furnished and had functioning light fixtures. LPAs toured the restrooms in all floors, and room 215, 219, 310, and 329. All restrooms had grab bars installed. Residents' bathrooms had nonskid floors. Hot water temperature was measured, out of range of 105 to 120 degrees F. The elevator was functioning in the facility. There were functioning refrigerators in the kitchen. The centrally stored medication rooms in each floor were locked, ready for storage. LPA Ng observed the carbon monoxide/smoke detectors and alarms were functioning. LPA Ng randomly inspected the fire extinguishers in each floor. They were fully charged, last serviced in 10/13/2020. There was no open body of water outside the facility. There was no obstruction in all passageways inside the facility, and there was no obstruction in any of the emergency exits. Egress doors were tested and functioning. At 11:55 AM, Component III orientation was given to ED. The following issues needed to be fixed before LPAs could recommend licensure: Hot water temperature had to be between 105 and 120 degrees F. Evacuation chairs had to be installed in each stairwell. A complaint poster (PUB 475) should be the size of 20 x 26". The facility had a valid liability insurance . Once LPA Ng received the proof of corrections, a recommendation would be submitted to the Centralized Applications Bureau (CAB) and a final review of the application would be conducted. The application was subject to final approval by CAB. Additional requirements might still be required. This report was reviewed with ED and a copy was provided.

Citations

No citations recorded on this visit

The inspector found no violations of California child care regulations during this visit.

FAQ · About this visit

Common questions about this visit

What happened during the May 13, 2021 inspection of SONNET HILL?

This was an other inspection of SONNET HILL on May 13, 2021. The inspection found no deficiencies and no citations were issued.

Were any citations issued to SONNET HILL on May 13, 2021?

No citations were issued during this inspection. The facility was found to be in compliance with all applicable regulations.

What type of inspection was this?

This was an other inspection. other inspections are conducted by CCLD as part of their licensing oversight.

Share this reportEmail

Next steps

If this is your facility,claim this pageand correct anything the record gets wrong. Free.

Researching this visit professionally?Book a 15-minute calland we will walk through what we have on file.

Data from CCLD public records. Last updated . If you believe any information is inaccurate, report it here.