Skip to main content

Inspection visit

Follow-up

IVANHOE ELEMENTARY SCHOOL PRESCHOOLLicense 5438013021 citation on this visit
1 citation recorded

Inspector’s narrative

What the inspector wrote

On 1/25/2022, LPA Jose Penate arrived at facility to conduct a Case Management inspection due to a previous inspection visit. LPA Penate spoke with Lead Teacher, Casey Pulaski and discussed the purpose of the inspection. A tour of the facility was conducted both inside and outside and census was taken. Based on interviews that were conducted, it was determined that the staff at the facility utilized an Unapproved classroom for children during a power outage. LPA confirmed that the power was out on Monday, October 25 th and Tuesday, October 26 th . On both days the staff decided to use classroom #1 and that classroom was not fire cleared to have any children in the room at that time. Per California Code of Regulations, Title 22, Division 12, the following deficiency is being cited on the attached LIC809-D, see next page. Exit interview was conducted with Lead Teacher, Casey Pulaski. A Notice of Site Visit Form was posted and must remain posted for 30 days. The licensee was provided a copy of their appeal rights and their signature on this form acknowledges receipt of this form.

Citations

1 citation recorded*CCLD

What does Type A vs Type B mean?

Type A. Serious citation. Imminent or substantial risk to children. The regulator requires corrective action immediately and may impose a civil penalty.

Type B. Lower-severity citation. Corrective action required, no imminent risk. The regulator monitors compliance on the next visit.

  • 101161(a)Type B

    LIMITATIONS ON CAPACITY

    A licensee shall not operate a child care center beyond the conditions and limitations specified on the license, including the capacity limitation. LPA confirmed that the power was out on Monday, October 25th and Tuesday, October 26th. On both days the staff decided to use classroom #1 and that classroom was not fire cleared to have any children in the room at that time. This is an potential health and safety risk to children in care.

FAQ · About this visit

Common questions about this visit

What happened during the January 25, 2022 inspection of IVANHOE ELEMENTARY SCHOOL PRESCHOOL?

This was a other inspection of IVANHOE ELEMENTARY SCHOOL PRESCHOOL on January 25, 2022. 1 citation were issued: 1 Type B.

Were any citations issued to IVANHOE ELEMENTARY SCHOOL PRESCHOOL on January 25, 2022?

Yes, 1 citation was issued (0 Type A, 1 Type B). The first citation was for: "A licensee shall not operate a child care center beyond the conditions and limitations specified on the license, includi..."

What type of inspection was this?

This was a other inspection. other inspections are conducted by CCLD as part of their licensing oversight.

SourceView on CCLDView original report

Share this reportEmail

Next steps

If this is your facility,claim this pageand add your response to the public record. Free.

Spotted an inaccuracy on this visit?Request a reviewand we will check it against the public record.

Researching this visit professionally?Book a 20-minute calland we will walk through what we have on file.

Data from CCLD public records. Last updated . If you believe any information is inaccurate, report it here.