Inspection visit

Fire Safety inspection

Villa Maria Post AcuteCMS #05583014 citations on this visit
14 citations recorded

Citations

14 citations recorded*CMS

This is a Fire Safety survey. CMS cites these findings under the Life Safety Code and Emergency Preparedness rules, a separate set from the health (F-tag) deficiencies. The codes and grading differ, so these do not link to the health violation pages.

What do CMS severity letters mean?

Serious (G-L). Actual harm to a resident, or immediate jeopardy. Codes G through I indicate actual harm; J through L indicate immediate jeopardy to resident health or safety.

General (A-F). No actual harm found, or harm that is minimal. The facility must still submit a Plan of Correction. Most CMS citations land here.

Each letter combines severity with scope: how many residents the deficiency affected.

  • 0918GeneralS&S Fpotential for harm

    Have generator or other power source capable of supplying service within 10 seconds.

  • 0015GeneralS&S Cno actual harm

    Address subsistence needs for staff and patients.

  • 0025GeneralS&S Fpotential for harm

    Create arrangements with other facilities to receive patients.

  • 0026GeneralS&S Fpotential for harm

    Establish roles under a Waiver declared by secretary.

  • 0031GeneralS&S Cno actual harm

    Provide emergency officials' contact information.

  • 0039GeneralS&S Cno actual harm

    Conduct testing and exercise requirements.

  • 0223GeneralS&S Dpotential for harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

  • 0324GeneralS&S Dpotential for harm

    Provide properly protected cooking facilities.

  • 0325GeneralS&S Dpotential for harm

    Have properly installed hallway dispensers for alcohol-based hand rub.

  • 0353GeneralS&S Cno actual harm

    Inspect, test, and maintain automatic sprinkler systems.

  • 0355GeneralS&S Dpotential for harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

  • 0372GeneralS&S Fpotential for harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

  • 0511GeneralS&S Dpotential for harm

    Have properly installed electrical wiring and gas equipment.

  • 0741GeneralS&S Dpotential for harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

FAQ · About this visit

Common questions about this visit

What happened during the July 25, 2025 survey of Villa Maria Post Acute?

This was a inspection survey of Villa Maria Post Acute on July 25, 2025. The surveyor cited 14 deficiencies, recorded on the federal Form 2567 statement of deficiencies.

Were any deficiencies cited at Villa Maria Post Acute on July 25, 2025?

Yes, 14 deficiencies were cited, each with a CMS Scope and Severity grade. The first was: "Have generator or other power source capable of supplying service within 10 seconds."

What type of survey was this?

This was a inspection survey conducted by state surveyors under federal Centers for Medicare & Medicaid Services (CMS) oversight. Findings are published on CMS Care Compare.