Citations

53 citations on record

Each deficiency cited on a CMS health inspection of this facility, sourced from the federal record. Open a report for the raw CMS Scope and Severity grade on each finding.

What do CMS severity letters mean?

Serious (G-L). Actual harm to a resident, or immediate jeopardy. Codes G through I indicate actual harm; J through L indicate immediate jeopardy to resident health or safety.

General (A-F). No actual harm found, or harm that is minimal. The facility must still submit a Plan of Correction. Most CMS citations land here.

Each letter combines severity with scope: how many residents the deficiency affected.

  • 0363Generalpotential for harm

    Install corridor and hallway doors that block smoke.

  • 0372Generalpotential for harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

  • 0511Generalpotential for harm

    Have properly installed electrical wiring and gas equipment.

  • 0625Generalpotential for harm

    Notify the resident or the resident’s representative in writing how long the nursing home will hold the resident’s bed in cases of transfer to a hospital or therapeutic leave.

  • 0761Generalpotential for harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

  • 0712Generalpotential for harm

    Have simulated fire drills held at unexpected times.

  • 0521Generalpotential for harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

  • 0324Generalpotential for harm

    Provide properly protected cooking facilities.

  • 0321Generalpotential for harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

  • 0291Generalpotential for harm

    Install emergency lighting that can last at least 1 1/2 hours.

  • 0222Generalpotential for harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

  • 0004Generalpotential for harm

    Develop and maintain an Emergency Preparedness Program (EP).

  • 0920Generalpotential for harm

    Ensure proper usage of power strips and extension cords.

  • 0758Generalpotential for harm

    Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.

  • 0036Generalpotential for harm

    Establish emergency prep training and testing.

  • 0918Generalpotential for harm

    Have generator or other power source capable of supplying service within 10 seconds.

  • 0901Generalpotential for harm

    Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

  • 0037Generalpotential for harm

    Establish staff and initial training requirements.

  • 0211Generalpotential for harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

  • 0353Generalpotential for harm

    Inspect, test, and maintain automatic sprinkler systems.

  • 0321Generalpotential for harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

  • 0222Generalpotential for harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

  • 0291Generalpotential for harm

    Install emergency lighting that can last at least 1 1/2 hours.

  • 0345Generalpotential for harm

    Have approved installation, maintenance and testing program for fire alarm systems.

  • 0920Generalpotential for harm

    Ensure proper usage of power strips and extension cords.

  • 0353Generalpotential for harm

    Inspect, test, and maintain automatic sprinkler systems.

  • 0355Generalpotential for harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

  • 0362Generalpotential for harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

  • 0363Generalpotential for harm

    Install corridor and hallway doors that block smoke.

  • 0712Generalpotential for harm

    Have simulated fire drills held at unexpected times.

  • 0901Generalpotential for harm

    Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

  • 0914Generalpotential for harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

  • 0550Generalpotential for harm

    Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.

  • 0732Generalno actual harm

    Post nurse staffing information every day.

  • 0758Generalpotential for harm

    Implement gradual dose reductions(GDR) and non-pharmacological interventions, unless contraindicated, prior to initiating or instead of continuing psychotropic medication; and PRN orders for psychotropic medications are only used when the medication is necessary and PRN use is limited.

  • 0914Generalpotential for harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

  • 0918Generalpotential for harm

    Have generator or other power source capable of supplying service within 10 seconds.

  • 0756Generalpotential for harm

    Ensure a licensed pharmacist perform a monthly drug regimen review, including the medical chart, following irregularity reporting guidelines in developed policies and procedures.

  • 0880Generalpotential for harm

    Provide and implement an infection prevention and control program.

  • 0757Generalpotential for harm

    Ensure each resident’s drug regimen must be free from unnecessary drugs.

  • 0374Generalpotential for harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

  • 0354Generalpotential for harm

    Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.

  • 0353Generalpotential for harm

    Inspect, test, and maintain automatic sprinkler systems.

  • 0345Generalpotential for harm

    Have approved installation, maintenance and testing program for fire alarm systems.

  • 0321Generalpotential for harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

  • 0291Generalpotential for harm

    Install emergency lighting that can last at least 1 1/2 hours.

  • 0161Generalpotential for harm

    Use approved construction type or materials.

  • 0009Generalpotential for harm

    Include a process for Emergency Preparedness collaboration.

  • 0920Generalpotential for harm

    Ensure proper usage of power strips and extension cords.

  • 0324Generalpotential for harm

    Provide properly protected cooking facilities.

  • 0511Generalpotential for harm

    Have properly installed electrical wiring and gas equipment.

  • 0712Generalpotential for harm

    Have simulated fire drills held at unexpected times.

  • 0761Generalpotential for harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

Inspection history

Every health inspection on record

Each CMS health inspection of this facility, and the deficiencies the surveyors cited. Where the verbatim Form 2567 statement of deficiencies is on file, it links to the full report.

FAQ

Questions and answers

What is Lexington Park Nursing & Post Acute Center?
Lexington Park Nursing & Post Acute Center is a Medicare- and Medicaid-certified nursing home in Topeka, KS, tracked by the Centers for Medicare & Medicaid Services (CMS). Its CMS Certification Number (CCN) is 175154.
What is the CMS rating for Lexington Park Nursing & Post Acute Center?
Lexington Park Nursing & Post Acute Center has a CMS overall rating of 5 out of 5 stars. CMS rates nursing homes on health inspections, staffing, and quality measures.
How many beds does Lexington Park Nursing & Post Acute Center have?
Lexington Park Nursing & Post Acute Center is certified for 90 beds. It serves an average of 80.2 residents per day.
How many citations does Lexington Park Nursing & Post Acute Center have?
Lexington Park Nursing & Post Acute Center has 53 citations on record from CMS health inspections, each tied to a federal deficiency tag.
When was Lexington Park Nursing & Post Acute Center last inspected?
Lexington Park Nursing & Post Acute Center was last inspected on July 17, 2024. CMS surveys nursing homes about once a year and after complaints.
What can I do if I have concerns about care at this facility?
Start by raising the concern with the facility administrator or director of nursing. Every state also runs a free long-term care ombudsman program that advocates for residents and families; the federal Eldercare Locator at eldercare.acl.gov can connect you with yours. Complaints about quality of care can also be filed with your state survey agency.

*Sourced from the Centers for Medicare & Medicaid Services (CMS). See the official record on CMS Care Compare. If you believe any information is inaccurate, report it here.

/nursing-home/175154-lexington-park-nursing-post-acute-center