Skip to main content

Inspection visit

Inspection

PILGRIM REHABILITATION & SKILLED NURSING CENTERCMS #22504816 citations on this visit
16 citations recorded

Citations

16 citations recorded*CMS

What do CMS severity letters mean?

Serious (G-L). Actual harm to a resident, or immediate jeopardy. Codes G through I indicate actual harm; J through L indicate immediate jeopardy to resident health or safety.

General (A-F). No actual harm found, or harm that is minimal. The facility must still submit a Plan of Correction. Most CMS citations land here.

Each letter combines severity with scope: how many residents the deficiency affected.

  • 0695GeneralS&S Dpotential for harm

    F695 - Respiratory care, including tracheostomy care and tracheal suctioning

    Provide safe and appropriate respiratory care for a resident when needed.

  • 0222GeneralS&S Fpotential for harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

  • 0324GeneralS&S Epotential for harm

    Provide properly protected cooking facilities.

  • 0345GeneralS&S Epotential for harm

    Have approved installation, maintenance and testing program for fire alarm systems.

  • 0353GeneralS&S Fpotential for harm

    Inspect, test, and maintain automatic sprinkler systems.

  • 0372GeneralS&S Fpotential for harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

  • 0712GeneralS&S Epotential for harm

    F712 - Frequency of physician visits

    Have simulated fire drills held at unexpected times.

  • 0761GeneralS&S Fpotential for harm

    F761 - Labeling of Drugs and Biologicals

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

  • 0911GeneralS&S Epotential for harm

    F911 - Accommodate no more than four residents

    Meet requirements for the installation and maintenance of electrical systems.

  • 0918GeneralS&S Epotential for harm

    F918 - Bathroom Facilities

    Have generator or other power source capable of supplying service within 10 seconds.

  • 0920GeneralS&S Epotential for harm

    F920 - Dining and Resident Activities

    Ensure proper usage of power strips and extension cords.

  • 0550GeneralS&S Dpotential for harm

    F550 - Resident Rights

    Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.

  • 0656GeneralS&S Dpotential for harm

    F656 - Comprehensive Care Plans

    Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured.

  • 0698GeneralS&S Dpotential for harm

    F698 - Dialysis

    Provide safe, appropriate dialysis care/services for a resident who requires such services.

  • 0842GeneralS&S Dpotential for harm

    F842 - Resident-identifiable information

    Safeguard resident-identifiable information and/or maintain medical records on each resident that are in accordance with accepted professional standards.

  • 0909GeneralS&S Fpotential for harm

    F909 - Conduct Regular inspection of all bed frames, mattresses, and bed

    Regularly inspect all bed frames, mattresses, and bed rails (if any) for safety; and all bed rails and mattresses must attach safely to the bed frame.

FAQ · About this visit

Common questions about this visit

What happened during the January 30, 2025 survey of PILGRIM REHABILITATION & SKILLED NURSING CENTER?

This was a inspection survey of PILGRIM REHABILITATION & SKILLED NURSING CENTER on January 30, 2025. The surveyor cited 16 deficiencies, recorded on the federal Form 2567 statement of deficiencies.

Were any deficiencies cited at PILGRIM REHABILITATION & SKILLED NURSING CENTER on January 30, 2025?

Yes, 16 deficiencies were cited, each with a CMS Scope and Severity grade. The first was: "Provide safe and appropriate respiratory care for a resident when needed."

What type of survey was this?

This was a inspection survey conducted by state surveyors under federal Centers for Medicare & Medicaid Services (CMS) oversight. Findings are published on CMS Care Compare.

Share this reportEmail

Next steps

Concerned about a resident’s care?Find your local ombudsman through the Eldercare Locatoror file a complaint with your state survey agency.

Researching this visit professionally?Book a 15-minute calland we will walk through what we have on file.

Data from CMS Care Compare public records. Dataset last refreshed . If you believe any information is inaccurate, report it here.