Inspection visit

Fire Safety inspection

Odelia HealthcareCMS #32506031 citations on this visit
31 citations recorded

Citations

31 citations recorded*CMS

This is a Fire Safety survey. CMS cites these findings under the Life Safety Code and Emergency Preparedness rules, a separate set from the health (F-tag) deficiencies. The codes and grading differ, so these do not link to the health violation pages.

What do CMS severity letters mean?

Serious (G-L). Actual harm to a resident, or immediate jeopardy. Codes G through I indicate actual harm; J through L indicate immediate jeopardy to resident health or safety.

General (A-F). No actual harm found, or harm that is minimal. The facility must still submit a Plan of Correction. Most CMS citations land here.

Each letter combines severity with scope: how many residents the deficiency affected.

  • 0039GeneralS&S Fpotential for harm

    Conduct testing and exercise requirements.

  • 0041GeneralS&S Fpotential for harm

    Implement emergency and standby power systems.

  • 0100GeneralS&S Dpotential for harm

    Meet other general requirements.

  • 0211GeneralS&S Epotential for harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

  • 0222GeneralS&S Epotential for harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

  • 0223GeneralS&S Epotential for harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

  • 0291GeneralS&S Fpotential for harm

    Install emergency lighting that can last at least 1 1/2 hours.

  • 0293GeneralS&S Fpotential for harm

    Have properly located and lighted "Exit" signs.

  • 0321GeneralS&S Epotential for harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

  • 0345GeneralS&S Fpotential for harm

    Have approved installation, maintenance and testing program for fire alarm systems.

  • 0346GeneralS&S Fpotential for harm

    Follow proper procedures when the fire alarm was out of service for more than 4 hours.

  • 0351GeneralS&S Epotential for harm

    Install an approved automatic sprinkler system.

  • 0353GeneralS&S Fpotential for harm

    Inspect, test, and maintain automatic sprinkler systems.

  • 0354GeneralS&S Fpotential for harm

    Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.

  • 0363GeneralS&S Epotential for harm

    Install corridor and hallway doors that block smoke.

  • 0372GeneralS&S Fpotential for harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

  • 0374GeneralS&S Epotential for harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

  • 0521GeneralS&S Fpotential for harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

  • 0712GeneralS&S Fpotential for harm

    Have simulated fire drills held at unexpected times.

  • 0741GeneralS&S Fpotential for harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

  • 0761GeneralS&S Fpotential for harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

  • 0781GeneralS&S Dpotential for harm

    Have restrictions on the use of portable space heaters.

  • 0911GeneralS&S Epotential for harm

    Meet requirements for the installation and maintenance of electrical systems.

  • 0918GeneralS&S Fpotential for harm

    Have generator or other power source capable of supplying service within 10 seconds.

  • 0920GeneralS&S Fpotential for harm

    Ensure proper usage of power strips and extension cords.

  • 0923GeneralS&S Epotential for harm

    Have proper medical gas storage and administration areas.

  • 0926GeneralS&S Fpotential for harm

    Ensure that personnel concerned with handling of medical gases and cylinders are trained on the risk.

  • 0018GeneralS&S Fpotential for harm

    Establish procedures for tracking staff and patients during an emergency.

  • 0026GeneralS&S Fpotential for harm

    Establish roles under a Waiver declared by secretary.

  • 0029GeneralS&S Fpotential for harm

    Develop a communication plan.

  • 0031GeneralS&S Fpotential for harm

    Provide emergency officials' contact information.

FAQ · About this visit

Common questions about this visit

What happened during the May 30, 2025 survey of Odelia Healthcare?

This was a inspection survey of Odelia Healthcare on May 30, 2025. The surveyor cited 31 deficiencies, recorded on the federal Form 2567 statement of deficiencies.

Were any deficiencies cited at Odelia Healthcare on May 30, 2025?

Yes, 31 deficiencies were cited, each with a CMS Scope and Severity grade. The first was: "Conduct testing and exercise requirements."

What type of survey was this?

This was a inspection survey conducted by state surveyors under federal Centers for Medicare & Medicaid Services (CMS) oversight. Findings are published on CMS Care Compare.