Inspection visit
Fire Safety inspection
Citations
25 citations recorded*CMS
This is a Fire Safety survey. CMS cites these findings under the Life Safety Code and Emergency Preparedness rules, a separate set from the health (F-tag) deficiencies. The codes and grading differ, so these do not link to the health violation pages.
What do CMS severity letters mean?
Serious (G-L). Actual harm to a resident, or immediate jeopardy. Codes G through I indicate actual harm; J through L indicate immediate jeopardy to resident health or safety.
General (A-F). No actual harm found, or harm that is minimal. The facility must still submit a Plan of Correction. Most CMS citations land here.
Each letter combines severity with scope: how many residents the deficiency affected.
- 0031GeneralS&S Fpotential for harm
Provide emergency officials' contact information.
- 0100GeneralS&S Fpotential for harm
Meet other general requirements.
- 0211GeneralS&S Epotential for harm
Keep aisles, corridors, and exits free of obstruction in case of emergency.
- 0222GeneralS&S Dpotential for harm
Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.
- 0281GeneralS&S Dpotential for harm
Install proper backup exit lighting.
- 0291GeneralS&S Fpotential for harm
Install emergency lighting that can last at least 1 1/2 hours.
- 0293GeneralS&S Dpotential for harm
Have properly located and lighted "Exit" signs.
- 0300GeneralS&S Epotential for harm
Meet other general requirements that are deficient.
- 0321GeneralS&S Dpotential for harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
- 0345GeneralS&S Fpotential for harm
Have approved installation, maintenance and testing program for fire alarm systems.
- 0346GeneralS&S Fpotential for harm
Follow proper procedures when the fire alarm was out of service for more than 4 hours.
- 0353GeneralS&S Fpotential for harm
Inspect, test, and maintain automatic sprinkler systems.
- 0354GeneralS&S Fpotential for harm
Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.
- 0363GeneralS&S Epotential for harm
Install corridor and hallway doors that block smoke.
- 0372GeneralS&S Epotential for harm
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
- 0511GeneralS&S Fpotential for harm
Have properly installed electrical wiring and gas equipment.
- 0712GeneralS&S Fpotential for harm
Have simulated fire drills held at unexpected times.
- 0741GeneralS&S Fpotential for harm
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.
- 0761GeneralS&S Epotential for harm
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
- 0911GeneralS&S Epotential for harm
Meet requirements for the installation and maintenance of electrical systems.
- 0914GeneralS&S Epotential for harm
Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.
- 0926GeneralS&S Fpotential for harm
Ensure that personnel concerned with handling of medical gases and cylinders are trained on the risk.
- 0920GeneralS&S Dpotential for harm
Ensure proper usage of power strips and extension cords.
- 0325GeneralS&S Dpotential for harm
Have properly installed hallway dispensers for alcohol-based hand rub.
- 0918GeneralS&S Fpotential for harm
Have generator or other power source capable of supplying service within 10 seconds.
FAQ · About this visit
Common questions about this visit
What happened during the February 21, 2025 survey of Cedar Ridge Inn?
This was a inspection survey of Cedar Ridge Inn on February 21, 2025. The surveyor cited 25 deficiencies, recorded on the federal Form 2567 statement of deficiencies.
Were any deficiencies cited at Cedar Ridge Inn on February 21, 2025?
Yes, 25 deficiencies were cited, each with a CMS Scope and Severity grade. The first was: "Provide emergency officials' contact information."
What type of survey was this?
This was a inspection survey conducted by state surveyors under federal Centers for Medicare & Medicaid Services (CMS) oversight. Findings are published on CMS Care Compare.
SourceView on CMS Care Compare