Inspection visit
Inspection
Citations
18 citations recorded*CMS
What do CMS severity letters mean?
Serious (G-L). Actual harm to a resident, or immediate jeopardy. Codes G through I indicate actual harm; J through L indicate immediate jeopardy to resident health or safety.
General (A-F). No actual harm found, or harm that is minimal. The facility must still submit a Plan of Correction. Most CMS citations land here.
Each letter combines severity with scope: how many residents the deficiency affected.
F550 - Resident Rights
Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her rights.
F605 - Respect and Dignity
Prevent the use of unnecessary psychotropic medications or use medications that may restrain a resident's ability to function.
F802 - Staffing
Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
F812 - Food safety requirements
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
F814 - Food Safety Requirements
Dispose of garbage and refuse properly.
F838 - Facility assessment
Conduct and document a facility-wide assessment to determine what resources are necessary to care for residents competently during both day-to-day operations (including nights and weekends) and emergencies.
F880 - Infection Control
Provide and implement an infection prevention and control program.
F882 - Infection preventionist
Designate a qualified infection preventionist to be responsible for the infection prevent and control program in the nursing home.
- 0015GeneralS&S Dpotential for harm
Address subsistence needs for staff and patients.
- 0133GeneralS&S Dpotential for harm
Install a two-hour-resistant firewall separation.
- 0211GeneralS&S Epotential for harm
Keep aisles, corridors, and exits free of obstruction in case of emergency.
- 0225GeneralS&S Epotential for harm
Have stairways and smokeproof enclosures used as exits that meet safety requirements.
- 0321GeneralS&S Dpotential for harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
- 0345GeneralS&S Fpotential for harm
Have approved installation, maintenance and testing program for fire alarm systems.
- 0353GeneralS&S Dpotential for harm
Inspect, test, and maintain automatic sprinkler systems.
- 0511GeneralS&S Epotential for harm
Have properly installed electrical wiring and gas equipment.
F918 - Bathroom Facilities
Have generator or other power source capable of supplying service within 10 seconds.
F920 - Dining and Resident Activities
Ensure proper usage of power strips and extension cords.
FAQ · About this visit
Common questions about this visit
What happened during the August 1, 2025 survey of ELIZABETH CHURCH MANOR NURSING HOME?
This was a inspection survey of ELIZABETH CHURCH MANOR NURSING HOME on August 1, 2025. The surveyor cited 18 deficiencies, recorded on the federal Form 2567 statement of deficiencies.
Were any deficiencies cited at ELIZABETH CHURCH MANOR NURSING HOME on August 1, 2025?
Yes, 18 deficiencies were cited, each with a CMS Scope and Severity grade. The first was: "Honor the resident's right to a dignified existence, self-determination, communication, and to exercise his or her right..."
What type of survey was this?
This was a inspection survey conducted by state surveyors under federal Centers for Medicare & Medicaid Services (CMS) oversight. Findings are published on CMS Care Compare.
SourceView on CMS Care Compare
Next steps
Concerned about a resident’s care?Find your local ombudsman through the Eldercare Locatoror file a complaint with your state survey agency.
Researching this visit professionally?Book a 15-minute calland we will walk through what we have on file.
Data from CMS Care Compare public records. Dataset last refreshed . If you believe any information is inaccurate, report it here.