F 0761
Level of Harm - Minimal harm
or potential for actual harm
Residents Affected - Some
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted
professional principles; and all drugs and biologicals must be stored in locked compartments, separately
locked, compartments for controlled drugs.
**NOTE- TERMS IN BRACKETS HAVE BEEN EDITED TO PROTECT CONFIDENTIALITY** Based on
observation, staff interview, and policy review, the facility failed to ensure medications were properly dated
when first accessed/ used. This involved three of four medication administration carts and affected a total of
eight residents (#30, #32, #50, #54, #55, #63, #75, and #77). The facility's census was 87.
Findings include:
1 a.) On 09/23/24 at 10:09 A.M., an observation of the 400 hall medication administration cart with
Licensed Practical Nurse (LPN) #35 revealed there were three multi-use vials of Lantus (slow acting insulin)
100 units/ milliliter (ml) 10 ml vials in the top drawer of the medication administration cart for Resident #32.
The vials were stored in one bag and all three vials had been opened. The label on the bag the insulin vials
were stored in provided directions under a high alert. The directions indicated the insulin should be
refrigerated and, once opened, it should be discarded after 28 days. There was a place on the label to
indicate the date when the vial had been opened. A date was not added on the label and none of the three
multi-use vials had a date written on them to show when they had been opened/ accessed. Findings were
verified by LPN #35 at the time of the observation.
There was also three vials of Lantus 100 units/ ml 10 ml vials in a bag for Resident #77. All three of the
vials had been opened and none of the three were dated when first accessed. The label on the bag the
insulin vials were being stored in included a high alert that indicated once opened it was to be discarded
after 28 days. The label included a place to write the date the vial was opened, but was intended to hold
only one vial. There was the numbers 7-16 written on the label, but it was not clear if that was a date one of
the vials had been opened or not. If it was a date one of the vials were opened, it would have exceeded the
28 days in which it should have been discarded. Findings were verified by LPN #35 at the time of the
observation.
Further review of the 400 hall medication administration cart revealed there was a small box in the top of
the medication cart that contained Latanoprost 0.005% ophthalmic (eye) solution for Resident #75. The
plastic bottle inside the box that held the eye drops had been opened. There was no date on the bottle or
the box to indicate when the medication bottle was opened. The label on the box the eye drops came in
provided direction on the storage of the medication. The label revealed the opened bottle could be stored at
room temperature and was to be discarded after six weeks. Without a date, it was not clear as to when the
ophthalmic eye drops should be discarded. Findings were verified by LPN #35 at the time of the
observation.
On 09/23/24 at 10:15 A.M., an interview with LPN #35 revealed all multi- use vials and other
(continued on next page)
Any deficiency statement ending with an asterisk (*) denotes a deficiency which the institution may be excused from correcting providing it is determined that other
safeguards provide sufficient protection to the patients. (See instructions.) Except for nursing homes, the findings stated above are disclosable 90 days following the
date of survey whether or not a plan of correction is provided. For nursing homes, the above findings and plans of correction are disclosable 14 days following the date
these documents are made available to the facility. If deficiencies are cited, an approved plan of correction is requisite to continued program participation.
LABORATORY DIRECTOR'S OR PROVIDER/SUPPLIER
REPRESENTATIVE'S SIGNATURE
TITLE
(X6) DATE
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Facility ID:
If continuation sheet
Page 1 of 3
Event ID:
365147
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
365147
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/24/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
Highland Oaks Health Center
4114 North State Route 376 NW
McConnelsville, OH 43756
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0761
Level of Harm - Minimal harm
or potential for actual harm
Residents Affected - Some
medications that were multi-use should be dated when first accessed/ opened. She confirmed you would
not know when to discard the medication, after it had been opened, in accordance with the instructions
included on the medication labels.
1 b.) On 09/23/24 at 10:35 A.M., an observation of the 300 hall medication administration cart with
Registered Nurse (RN) #500 present revealed there were three bottles of liquid medicine found in the
medication administration cart that was not dated when opened. One bottle was a stock bottle of Maalox 12
fluid ounce (355 ml) that was in the bottom drawer of the medication cart and had been opened. There was
no date on the outside of the bottle to indicate when it had been opened.
There was also a bottle of Lactulose solution 10 Grams (Gms)/ 15 ml for Resident #55 that had been
opened and not dated. A third bottle of [NAME]/ PSE/ DM syrup 2/30/10 for Resident #30 that was found in
one of the lower pull out drawers that had been opened. It was not dated after it had been opened. Findings
were verified by RN #50 at the time of the observation.
On 09/23/24 at 10:39 A.M., an interview with RN #500 revealed bottles containing liquid medication should
be dated when first opened. She was not able to determine when the three bottles found in the medication
administration cart had been opened.
1 c.) On 09/23/24 at 10:55 A.M., an observation of the medication administration cart for the 200 hall with
RN #100 present revealed there was a Lantus 100 unit/ ml flexpen that was found in the top drawer of the
medication cart that belonged to Resident #63. The flexpen had been used, but was not dated to reflect
when it was first used. The label on the bag the flexpen was stored in included a high alert that indicated
once opened it could be stored at room temperature for 26 days. There was a place on the label for them to
indicate the date it was opened but no date was added. Findings were confirmed with RN #100 at the time
of the observation. She confirmed flexpens should be dated when first used, so the nurses knew when to
discard them by.
There was a Novolog 100 unit/ ml flexpen for Resident #54 found in the top drawer of the 200 hall
medication cart that was being used. There was no date written on the flexpen or on the label on the bag
the flexpen was stored in that indicated when it had first been used. The label included a high alert that
directed the nurses the flexpen could be stored at room temperature for up to 28 days.
There was also two Tresiba (insulin) 100 units/ ml flexpens for Resident #50 that were found in the top
drawer of the medication cart. One of the flexpens was dated 09/12/24 to show when it was first used. The
other flexpen was not dated and could not be determined if it had been used or not. The label on the bag it
came in had a high alert that instructed the staff to refrigerate and once opened it could be stored at room
temperature for up to 65 days. RN #100 confirmed Resident #50 should not have two Tresiba flexpens
stored in the medication cart at the same time. She stated the flexpen that was not in use should have been
stored in the refrigerator, as the label indicated, until it was put in use. She further acknowledged all
multi-use flexpens should be dated when first used, so the nursing staff would know the date the flexpens
should be discarded by. She confirmed none of the insulin flexpens mentioned above had a date on the
flexpen or on the bag they came in to show when they were first used.
Review of the facility's policy on Storage of Medications (revised 04/2007) revealed the facility should store
all drugs and biologicals in a safe, secure, and orderly manner. Drugs and biologicals should be stored in
the packaging, containers or other dispensing systems in which they were received. Only the issuing
pharmacy was authorized to transfer medications between containers. The facility
(continued on next page)
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
365147
If continuation sheet
Page 2 of 3
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
365147
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/24/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
Highland Oaks Health Center
4114 North State Route 376 NW
McConnelsville, OH 43756
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0761
should not use discontinued, outdated, or deteriorated drugs or biologicals.
Level of Harm - Minimal harm
or potential for actual harm
This deficiency represents non-compliance investigated under Complaint Number OH00157490.
Residents Affected - Some
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
365147
If continuation sheet
Page 3 of 3