F 0641
Ensure each resident receives an accurate assessment.
Level of Harm - Minimal harm
or potential for actual harm
**NOTE- TERMS IN BRACKETS HAVE BEEN EDITED TO PROTECT CONFIDENTIALITY** Based on
interview and record review, the facility failed to ensure the assessment accurately reflected the resident's
status for 1 of 4 residents (Resident #64) reviewed for assessments, in that:
Residents Affected - Few
The facility failed to ensure Resident #64's Quarterly MDS assessment incorrectly documented the resident
as not receiving hospice care.
This failure could place residents at risk for inadequate care due to inaccurate assessments.
The findings were:
Record review of Resident #64's face sheet, dated 09/18/2023, revealed the resident was [AGE] years old
with an admission date of 02/19/2024 and a readmission date of 05/25/2024, Resident #64's with
diagnoses that included: Osteomyelitis(a serious infection of the bone that can be acute or chronic) ,
unspecified, Type II diabetes Mellitus with unspecified complications, End Stage Renal Disease.
Record review of THHS Texas Medicaid Hospice Program Individual Election/Cancellation/Update Form
3071 revealed Resident #64 elected hospice services effective 05/14/2024.
Record review of Resident #64's Quarterly MDS dated [DATE] revealed a BIMS score of 10 indicating
moderate cognitive impairment, and resident was not receiving hospice services.
During an interview with the MDS nurse on 09/18/2024 at 11:58 AM, the MDS nurse stated she had
completed the MDS. The MDS nurse stated Resident #64's Quarterly MDS was coded as the resident not
receiving hospice services and confirmed Resident #64 readmitted to the facility on [DATE] under Hospice.
MDS nurse confirmed that MDS should have been completed as a Significant Change MDS and reflected
hospice election. The MDS nurse revealed that the RAI was used as reference for the MDS and she had
access electronically to the RAI on her computer.
During an interview with the DON on 09/19/24 at 12:18 PM, the DON stated Resident #64 was receiving
hospice services and should have been coded as receiving hospice services on a Significant Change MDS.
The DON confirmed the RAI is used as reference for the MDS and expected MDS Nurse follow the RAI
reference. The MDS Nurse was responsible for ensuring accurate coding and the DON was responsible to
review for accuracy.
Record review of, Long-Term Care Facility Resident Assessment Instrument 3.0 User's Manual, Version
1.19.1, September 2024, revealed, An SCSA is required to be performed when a terminally ill resident
enrolls in a hospice program (Medicare-certified or State-licensed hospice provider) or changes
(continued on next page)
Any deficiency statement ending with an asterisk (*) denotes a deficiency which the institution may be excused from correcting providing it is determined that other
safeguards provide sufficient protection to the patients. (See instructions.) Except for nursing homes, the findings stated above are disclosable 90 days following the
date of survey whether or not a plan of correction is provided. For nursing homes, the above findings and plans of correction are disclosable 14 days following the date
these documents are made available to the facility. If deficiencies are cited, an approved plan of correction is requisite to continued program participation.
LABORATORY DIRECTOR'S OR PROVIDER/SUPPLIER
REPRESENTATIVE'S SIGNATURE
TITLE
(X6) DATE
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Facility ID:
If continuation sheet
Page 1 of 6
Event ID:
675800
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
675800
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/19/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
LA Vida Serena Nursing and Rehabilitation
711 Kings Way
Del Rio, TX 78840
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0641
hospice providers and remains resident at the nursing home.
Level of Harm - Minimal harm
or potential for actual harm
Residents Affected - Few
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
675800
If continuation sheet
Page 2 of 6
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
675800
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/19/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
LA Vida Serena Nursing and Rehabilitation
711 Kings Way
Del Rio, TX 78840
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0684
Provide appropriate treatment and care according to orders, resident’s preferences and goals.
Level of Harm - Minimal harm
or potential for actual harm
**NOTE- TERMS IN BRACKETS HAVE BEEN EDITED TO PROTECT CONFIDENTIALITY** Based on
observations, interviews, and record reviews the facility failed to ensure that residents received treatment
and care in accordance with professional standards of practice, the comprehensive person-centered care
plan, and the residents' choices for 1 of 9 residents (Resident #34) reviewed for treatments and care related
to enteral access devices.
Residents Affected - Few
The facility failed to ensure medications were administered according to acceptable standards and
practices related to enteral access devices when Resident #34's medications were not dissolved in water
for administration with a flush between each medication administered.
These failures could place residents with enteral access devices at risk of not receiving the intended
therapeutic effects of medications, having medical complications, or complications related to utilization of
enteral access devices, potentially leading to a decline in health and well-being.
Findings included:
Record review of the admission Record revealed Resident #34 was a [AGE] year-old male, originally
admitted on [DATE] .
Record review of the quarterly MDS assessment dated [DATE] revealed Resident #34 had a BIMS
summary score of 9, indicative of moderately impaired cognition. Resident #34's primary reason for
admission was cerebral infarction, unspecified [a type of stroke caused by blood clot or hemorrhage in the
brain]. Other active diagnoses included seizure disorder and malnutrition. Nutritional approaches included
feeding tube, with more than 51% of calories and 501 ml or more fluid intake received thru the feeding tube
per day.
Record review of the Order Summary Report printed on 09/18/2024 revealed: flush enteral tube with 30 ml
of water between each medication; flush enteral tube with 60 ml of water before and after medication and
feedings; with a start date of 02/25/2021 Medications included: metoprolol [for high blood pressure] the a
start date of 07/08/2021, aspirin [for stroke] with a start date of 01/20/2023, Keppra [for seizures] with a
start date of 11/04/2022, folic acid [for supplement] with a start date of 09/08/2024, Celexa [for depression]
with a start date of 04/27/2022, losartan [for high blood pressure] with a start date of 02/26/2021,
multivitamin [for malnutrition], and thiamine [for supplement] ] with a start date of 02/26/2021.
Record review of the Care Plan revealed Resident #34 had the following focus areas: seizure disorder, high
blood pressure, potential for pressure injury, potential fluid deficit, on psychotropic medication related to
depression, seasonal allergies, muscle spasms, and polyneuropathy [nerve damage at multiple sites can
result in chronic and acute pain]; with the following associated interventions: give medications as ordered
with a date initiated of 02/25/2021.
In an observation on 09/18/2024 at 7:45 AM, LVN A prepared medications for Resident #34 by individually
crushing each tablet or pill and pouring liquids in separate souffle cups for administration via the enteral
access device. The medications were not mixed with water to dissolve. The [NAME] tions included
metoprolol tartrate 25 mg, give 0.5 tablet [given for high blood pressure]; aspirin 81 mg [given for history of
stroke]; Keppra 7.5 ml solution [given for seizures]; folic acid [for supplement]; Celexa 10 mg, give 0.5 tablet
[given for depression]; Losartan 25 mg [given for high blood
(continued on next page)
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
675800
If continuation sheet
Page 3 of 6
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
675800
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/19/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
LA Vida Serena Nursing and Rehabilitation
711 Kings Way
Del Rio, TX 78840
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0684
Level of Harm - Minimal harm
or potential for actual harm
Residents Affected - Few
pressure]; fexofenadine 180 mg [given for seasonal allergies]; multivitamin, and thiamine [given for
supplemental nutrition.
In an observation on 09/18/2024 beginning at 7:55 AM, LVN A assessed the placement of the enteral
access device for Resident #34 by aspiration with no fluids returned. LVN A flushed the enteral access
device with 60 ml of water. When the water level got to near the bottom of the syringe, approximately 1 to 3
ml of water, LVN A then added the powder of the first crushed medication to the syringe, then added the 30
ml of water flush to the syringe. As the water and medication mixture then drained into the enteral access
device, LVN A then added the powder from the next crushed medication to the last 1 to 3 ml mixture of
water and previous medications to the syringe, adding the 30 ml flush of water after. Powder residue could
be observed at the top of the 60 ml syringe, and at one point a brownish-beige frothy particulate could be
seen coating the walls of the barrel of the syringe. LVN A swirled the syringe while attached to the enteral
access device to have all the solid matter trapped by water and drain down the syringe into the enteral
access device. After each medication was added to the dregs of the liquid in the barrel, LVN A added 30 ml
water, including when she administered the liquid Keppra solution. After the last medication was
administered LVN A flushed the syringe with 60 ml of water, clamped the enteral access device, capped the
distal end of the enteral access device, and replaced the tube under Resident #34's shirt.
In an interview on 9/18/2024 at 8:00 AM, Resident #34 stated he did not want breakfast and declined the
supplement. Resident #34 stated he would see what was on the breakfast tray when it arrived, and he
would decide then if he was hungry enough to eat.
In an interview on 9/18/2024 at 8:03 AM, LVN A stated that either method, mixing the powder of a crushed
medication in a few ml of water to dissolve or adding it directly to the syringe, would be correct. LVN A
stated that adding the powder of a crushed medication directly to the syringe is how she almost always
administered medication to an enteral access device, unless there were specific orders to do it differently.
In an interview on 9/18/2024 at 8:40 AM, the DON stated she believed an enteral medication could be
added directly to the syringe once crushed as long as there was still some liquid at the bottom of the
syringe, and then immediately added the flush as per MD orders.
In an interview on 9/18/2024 at 11:35 AM, R.Ph. stated that the order of operations for an enteral tube
medication administration should be: 1.) check tube placement first [aspiration of fluids from the enteral
access device to visually inspect color and character]; 2.) ensure patency [being unclogged, allowing flow]
with a flush in the amount of water as ordered by the MD; 3.) crush each suitable tablet or pill into its own
souffle cup with 10 to 15 ml of water; 4.) allow each medication to flow by gravity; 5.) after each medication
flush in the amount of water as ordered by the MD; 6.) repeat as necessary and after the last medication
flush in the amount of water as ordered by the MD. R.Ph. stated the initial and final flushes at the beginning
and end of a medication administration were usually slightly larger, but depended on the amount the MD
determined was appropriate. R.Ph. stated the frothy brownish beige particulate was most likely not a
reaction between medications, but more likely the inert ingredients coming in contact with air, water and
turbulence. R.Ph. stated she would have to review the resident's profile to give more specific details. R.Ph.
stated she would call me back in about an hour as she was driving and en route to another facility at the
time of the interview.
In an interview on 9/18/2024 at 12:26 PM, the MD stated Resident #34 had originally been admitted
(continued on next page)
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
675800
If continuation sheet
Page 4 of 6
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
675800
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/19/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
LA Vida Serena Nursing and Rehabilitation
711 Kings Way
Del Rio, TX 78840
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0684
Level of Harm - Minimal harm
or potential for actual harm
Residents Affected - Few
for stroke some time back, but recently exhibited stroke like symptoms. The MD stated Resident #34's
diagnostics came back as negative for a stroke; however, he had more difficulty with speech and swallowing
after the stroke like symptoms were noted; which was why Resident #34 had an enteral access device
placed. The MD stated he was not sure if the resident was quite at the point where he could take his
medications by mouth, crushed in a puree at this point, but that was something therapy was working
towards with him. The MD stated he did not believe there was much of a risk in the small amount of
medications being mixed in the syringe as described in the observation above. The MD stated there would
be some expectation of medication residual in the souffle cup if the medication had been dissolved in water
that would approximate the amount of medication observed at the top of the syringe as described in the
observation above. The MD stated his expectation was that the crushed medications be dissolved in a small
amount of water and flushed as per orders. MD stated that he would consult with the pharmacist for best
practice on this issue in regard to Resident #34.
In an interview on 9/18/2024 at 2:37 PM, R.Ph. stated that she had reviewed the medication profile for
Resident #34, and she did not see any medications that would have an adverse reaction if administered in
the fashion as described in the observation above. R.Ph. stated that the best practice would be to place a
medication in pill or tablet form in a syringe with 15 to 30 ml of water and allow it to become a slurry
[semiliquid mixture of denser solids suspended in liquid] over approximately 20 minutes. Alternatively,
medications could be dissolved in a small amount of water for administration via an enteral access device
and followed with a prescribed amount of water to ensure the medication reaches the resident and does not
interfere with the patency of the enteral access device.
Record review of the facility's policy entitled Enteral Medication Administration, revised 1/25/2013, reflected
the following procedure: flush the tube with 30 ml or according to physician order; administer one
medication at a time, with a flush of 5-10 ml water or the amount ordered by the physician, between each
medication and after the medication is administered; verify that the medication cups are clear of any
remnants of crushed pills or liquid medication; once all medications have been administered flush the tube
with 30 ml of water or according to the physician order.
Review of website Nursing 2024, article titled Administering medication through a gastrostomy tube, dated
December 2022, accessed from
Nursing202https://journals.lww.com/nursing/fulltext/2002/12000/administering_medication_through_a_gastrostomy.14.aspx
(lww.com), accessed on 09/20/2024, revealed: .Release the GT [enteral access device] clamp. To verify
tube placement and patency, aspirate for gastric contents, note the residual volume, and follow your
facility's policy for re-instilling it . let the water flow by gravity to flush it .Pour the diluted medication into the
syringe and release the tubing to administer it. If you're giving more than one drug, flush between each
dose with 15 to 30 ml of water. When finished, flush with 30 ml of water, clamp the GT, and replace the plug
.
Review of ASPEN Safe Practices for Enteral Nutrition Therapy, accessed from
https://aspenjournals.onlinelibrary.[NAME].com/doi/10.1177/0148607116673053, accessed on 09/2024,
In Step 11 of Practice Recommendations, under the subheading for Medication Delivery via Enteral Access
Devices [feeding tubes], it states Prepare approved immediate-release solid dosage forms of medication for
enteral administration according to pharmacist instructions. Techniques may include: a. Crush simple
compressed tablets to a fine powder and mix with purified water. b. Open hard gelatin capsules and mix
powder containing the immediate release medication with purified water. Further, recommendations are to
avoid mixing together different medications intended for administration through the feeding tube [enteral
access device]; Inappropriate utilization of the feeding tube can result in complications include impairing the
patency of the feeding tube, reducing therapeutic effect of
(continued on next page)
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
675800
If continuation sheet
Page 5 of 6
Printed: 05/15/2026
Form Approved OMB
No. 0938-0391
Department of Health & Human Services
Centers for Medicare & Medicaid Services
STATEMENT OF DEFICIENCIES
AND PLAN OF CORRECTION
(X1) PROVIDER/SUPPLIER/CLIA
IDENTIFICATION NUMBER:
(X2) MULTIPLE CONSTRUCTION
675800
B. Wing
A. Building
(X3) DATE SURVEY
COMPLETED
09/19/2024
NAME OF PROVIDER OR SUPPLIER
STREET ADDRESS, CITY, STATE, ZIP CODE
LA Vida Serena Nursing and Rehabilitation
711 Kings Way
Del Rio, TX 78840
For information on the nursing home's plan to correct this deficiency, please contact the nursing home or the state survey agency.
(X4) ID PREFIX TAG
SUMMARY STATEMENT OF DEFICIENCIES
(Each deficiency must be preceded by full regulatory or LSC identifying information)
F 0684
the medication, or increasing drug toxicity; Complications include impairing the patency of the feeding tube,
reducing therapeutic effect of the medication, or increasing drug toxicity.
Level of Harm - Minimal harm
or potential for actual harm
Residents Affected - Few
FORM CMS-2567 (02/99)
Previous Versions Obsolete
Event ID:
Facility ID:
675800
If continuation sheet